205 Storm Indicator
The 205 Storm Indicator is a stainless steel washdown weight indicator designed for general-purpose weighing applications. It supports up to 8 load cells, includes 4 RS232 serial ports, and offers USB-B standard connectivity with USB-A available as an option.
- Description
- Product Specifications
Description
The 205 Storm Indicator is suitable for bench scales, floor scales, overhead track scales, tank and hopper systems, livestock scales, and truck scale applications. Its stainless steel IP67 enclosure allows for reliable operation in harsh and washdown environments.
With Gross, Tare, and Net conversion, StableSENSE adjustable filtering, selectable key lockout, flexible print formats, selectable weighing units, auto shutoff, and sleep mode, the 205 Storm provides practical control for demanding weighing systems.
Key Features
- Stainless steel wall or desk-mount enclosure
- IP67 enclosure rating
- 6-digit red LED display
- Gross, Tare, and Net conversion
- StableSENSE adjustable filtering
- Selectable key lockout
- Flexible print formats
- Auto shutoff and sleep mode
- 4 RS232 serial ports
- USB-B standard, USB-A optional
- Supports up to 8 load cells
- NTEP, OIML, Measurement Canada, Australian NSC, ETL, and CE approvals
Applications
- Bench scale systems
- Floor scale systems
- Tank and hopper weighing
- Livestock weighing
- Truck scale systems
| Model | 205 Storm Indicator |
|---|---|
| Product Type | Washdown weight indicator |
| Enclosure | Stainless steel wall or desk-mount enclosure |
| Enclosure Rating | IP67 |
| Display | 6-digit, 7-segment red LED display |
| Digit Height | 15mm |
| Keypad | 7-key colour-coded membrane keypad |
| Load Cell Support | Up to 8 × 350-ohm load cells |
| Enclosure Size | 233 × 191 × 79mm |
| Indicator Weight | 3.7kg |
| Power Requirements | 100 to 240 VAC, 50/60 Hz, 0.4A max. |
|---|---|
| Compensated Temperature Range | -10°C to 40°C |
| Operating Temperature Range | -23°C to 50°C |
| Humidity | 0 to 90%, non-condensing |
| Transducer Excitation | 9.4 VDC |
| Signal Input Range | 1.0 mV minimum to 31 mV maximum, with dead load boost |
| Internal Resolution | 1 part in 16,777,216 |
| Tare Capacity | Scale capacity |
| Sample Rate | 1 to 100 samples per second, selectable |
| Auto Zero Range | 0.5 or 1 through 9 divisions |